HP XP P9000 Command View Advanced Edition Suite Software 7.6.0-00 CLI Reference Guide
thpType=-1
consumedCapacityInKB=-1
thpPoolID=-1
threshold=-1
tcaPoolID=-1
thpPoolVolControlFlag=-1
managementAreaPoolID=-1
.
. (repeated for other ReplicationInfo instances)
.
*****: The values are encoded by the CLI.
GetStorageArray (subtarget=TieringPolicy)
GetStorageArray (subtarget=TieringPolicy) obtains information about tiering policies that
can be applied to Smart volumes of P9500.
NOTE:
If the microcode version of P9500 is not 70-05-00-XX/XX or later, some attributes cannot output
valid values. For details about output items, see “TieringPolicy instance” on page 411.
Parameters
Table 65 GetStorageArray (subtarget=TieringPolicy) command parameters
DescriptionStatusParameter name
Specify TieringPolicy.
Required
subtarget
Serial number of the storage system.
If you omit this parameter, all the storage systems become the
target.
Optional
serialnum
Model of the storage system
If you omit this parameter, all the storage systems become the
target.
Optional
model
Tiering policy ID for which information is to be obtained
If you specify this parameter, you must also specify the
serialnum and model parameters. If you specify this parameter
without specifying the serialnum and model parameters, the
information about all tiering policies in the storage system is
acquired.
For details about the values that can be specified, see the
description of the tieringpolicy parameter in the Table 78
.
If you omit this parameter, all the tiering policies become the
target.
Optional
policyid
Command reference194