DescriptionStatusParameter name
Filter for selecting a THP/Smart volume
Specify either the pool ID of a THP/Smart pool, or Unassigned.
If you specify the pool ID of a THP/Smart pool, information about
the THP/Smart volumes assigned to that THP/Smart pool is
obtained.
If you specify Unassigned, information about THP/Smart
volumes not assigned to a THP/Smart pool is obtained.
This information cannot be obtained by the partitioned storage
administrator.
If you specify model and serialnum at the same time, the
specification for this parameter becomes invalid.
Optional
thpvolfilter
Starting sequence number of logical units for which information
is to be obtained
Specify this parameter when you want to obtain information for
a part of logical units in a specific storage system.
When the logical unit information is ordered by device number
(in ascending order) from 0, specify the first number in the
sequence of logical units that you want to obtain.
This parameter must be specified together with the
numOfElementsFilter, model, and serialnum parameters.
Optional
startElement-
NumFilter
Number of logical units for which information is to be obtained
Specify this parameter when you want to obtain information for
a part of logical units in a specific storage system. Specify the
number of logical units for which information is to be obtained.
This parameter must be specified together with the
startElementNumFilter, model, and serialnum
parameters.
The maximum recommended value is 16384.
Optional
numOfElements-
Filter
Device number of the logical unit
Specify this parameter to acquire information about a particular
logical unit.
For P9500 and XP24000/XP20000:
Specify this parameter as a decimal number or colon-delim-
ited hexadecimal number in the format ww:xx:yy, where
ww is the LDKC number, xx is the CU number, and yy is the
LDEV number. ww is optional. If ww is omitted, LDKC is as-
sumed to be 0.
For XP12000/XP10000/SVS200 and XP1024/XP128:
Specify this parameter as a decimal number or colon-delim-
ited hexadecimal number in the format xx:yy, where xx is
the CU number, and yy is the LDEV number.
If you specify this parameter, you must also specify the model
and serialnum parameters.
The execution results are output in decimal.
Optional
displayname