HP XP P9000 Command View Advanced Edition Suite Software 7.5.0-00 CLI Reference Guide (TB581-96348, July 2013)

Check the Device Manager server error code that is output in place of code and the storage system
error code that is output in place of description, and then take one of the following actions:
When the Device Manager server error code is other than 6400:
Perform the following procedure:
1. Execute the GetStorageArray command to check whether there is an error in the batch file.
2. Correct any error in the batch file.
3. Execute the batch functionality again.
When the Device Manager server error code is 6400:
When the error code of the storage system is one of the following values:
"1005,1003", "1005,1004", "1005,1005", "1005,1007", "1005,1018", "1005,1020",
"1005,1021", "1005,1025", "1005,1068", "1005,1134", "1005,1135", "1005,1350",
"1005,1363", "1005,1368", "1005,1600", "1005,1600", "1005,1904", "1005,6012",
"1005,6036", "1005,65660"
"2005,1002", "2005,1009", "2005,1010", "2005,1012", "2005,1013", "2005,1015",
"2005,1021", "2005,1028", "2005,1050", "2005,1126", "2005,1137", "2005,1182",
"2005,1185", "2005,1187", "2005,1196", "2005,1362", "2005,1365", "2005,1600",
"2005,1601", "2005,1904", "2005,1905", "2005,1921", "2005,2015", "2005,6012",
"2005,6036", "2005,65660", "2005,65672"
The configuration information of the Device Manager server and the configuration of the storage
system might not match. Perform the following procedure:
1. Execute the AddStorageArray command or RefreshStorageArrays command.
2. Execute the GetStorageArray command to check whether there is an error in the batch
file.
3. Correct any error in the batch file.
4. Execute the batch functionality again.
If you cannot still resolve this problem, collect the following information, and then contact your
HP Technical Support:
Device Manager CLI log file
Device Manager CLI properties file
Command line input
Batch file
Device Manager server log files
When the error code of the storage system is one of the following values:
"1005,1364", "1005,2009", "1005,2010", "1005,2013", "1005,2015", "1005,2032",
"1005,2082", "1005,2083", "1005,2098", "1005,2099", "1005,2500", "1005,2501",
"1005,3002"
"2005,2005", "2005,2009", "2005,2013", "2005,2032", "2005,2082", "2005,2083",
"2005,2084", "2005,2098", "2005,2099", "2005,2502", "2005,3002", "2005,3003",
"2005,3006"
Perform the following procedure:
1. Execute the AddStorageArray command or RefreshStorageArrays command.
Batch functionality424