HP StorageWorks XP Command View Advanced Edition software Device Manager server installation and configuration guide (web version) (T1780-96078, March 2008)
Device Manager network configuration
37
Table 2-3 Ports used for communication between the management server and storage
subsystems
Port
number
Originator Destination Remarks
161/udp
Management server XP512/XP48 -
162/udp
• XP512/XP48
• XP1024/XP128
• XP12000/XP10000/SVS200
• XP24000/XP20000
Management server -
1099/tcp
Management server
• XP1024/XP128
• XP12000/XP10000/SVS200
• XP24000/XP20000
-
51099/tc
p
Management server
• XP1024/XP128
• XP12000/XP10000/SVS200
• XP24000/XP20000
-
51100/tc
p
Management server
• XP24000/XP20000
This setting is required for
obtaining Thin
Provisioning pool
information.
Table 2-4 Ports used for communication between the management server and CIM client
Port
number
Originator Destination Remarks
427/tcp
CIM client Management server -
5988/tcp
*
CIM client Management server This setting is required when
non-SSL communication is
used.
5989/tcp
*
CIM client Management server This setting is required when
SSL communication is used.
* This port number can be changed.
Table 2-5 Port used for communication between the management server and mail server
Port
number
Originator Destination Remarks
25/tcp
*
Management server
(Device Manager server)
Mail server
(for the email notification
function of the Device Manager
server)
This setting is required when
the email notification function
of the Device Manager server
is used.