HP StorageWorks XP Command View Advanced Edition Software 6.4 Server Administrator Guide for Device Manager and Provisioning Manager (web) (T1780-96341, July 2010)

Table Of Contents
Settings for CIM/WBEM (SMI-S CIMOM)
122
An XP RAID Manager library whose version is 01.12.04 or later
For details on how to install the Device Manager agent, see the HP StorageWorks XP
Command View Advanced Edition software Device Manager agent administrator guide.
2. Specify settings for central management. (This is recommended.)
3. Write the command device settings into the perf_cmddev.properties file.
To write the settings into the file, execute the perf_findcmddev command or edit the file
directly. For details about the settings in the file, see section
7-7-2-4 .
For details about the perf_findcmddev command, see section
7-7-2-5 .
NOTE:
If you are using the Device Manager agent version 6.3 or earlier and you want to use a storage
subsystem in an SLPR environment, directly edit the perf_cmddev.properties file to define
command devices for SLPRs.
If you upgrade the Device Manager agent from version 6.3 or earlier to version 6.4 or later, the settings in
the perf_cmddev.properties file remain unchanged. If you are using a storage subsystem in an
SLPR environment, after the upgrade installation finishes, refresh the information of SLPR command
devices defined in the perf_cmddev.properties file.
7-7-2-3 Preparations in the Device Manager server
For the Device Manager server property, specify the name of the host that acquires performance
information.
Specify the name of the host on which the Device Manager agent is installed by directly editing the
server.cim.agent property in the server.properties file on the Device Manager server. For
details on setting this property, see section
A-2-24.
After the property is set, restart the Device Manager server.
NOTE: Make sure that the host name specified for the server.cim.agent property matches
the host name registered in Device Manager for the host that acquires performance information. If
these host names are different, you cannot acquire performance information.
7-7-2-4 Settings in the perf_cmddev.properties file
Edit the perf_cmddev.properties file to define the command device of the target storage
subsystem.
The perf_cmddev.properties file is stored in the following location:
In Windows:
installation-folder-for-the-Device-Manager-
agent\mod\hdvm\config\perf_cmddev.properties
In Linux:
/opt/HDVM/HBaseAgent/mod/hdvm/config/perf_cmddev.properties
Use the following format to define the command device in the perf_cmddev.properties file.
Define one command device per line.
When using the Device Manager agent version 6.3 or earlier:
RAID-ID.serial-number.LDEV-number:deviceFileName
When using the Device Manager agent version 6.4 or later:
RAID-ID.serial-number.[SLPR-number.]LDEV-number:deviceFileName
The following table describes the values to be specified in the perf_cmddev.properties file.