HP StorageWorks P9000 Tiered Storage Manager Software 7.1 CLI Reference Guide (TB585-96011, May 2011)
Legend:
[ ]: Indicates output only when either the -d or the --detail option is specified.
NOTE:
For storage tiers created by using pool filter conditions, a hyphen (-) is displayed for some output
items because there is no relevant information to be output.
Example and execution results
• Command execution example (1):
In this example, detailed information is obtained for both the MegaTech-HighCost and
MyStorageTier storage tiers, in the MegaTechXP12000-Primary storage domain.
htsmcli GetStorageTiers --detail
storagedomainname="MegaTechXP12000-Primary"
name="MegaTech-HighCost,MyStorageTier"
• Execution results (1):
RESPONSE:
An instance of StorageDomain(1 of 1)
name=MegaTechXP12000-Primary
List of 2 StorageTier elements:
An instance of StorageTier(1 of 2)
name=MegaTech-HighCost
filterCondition=RAIDLevel = 'RAID5(3D+1P)' AND Capacity < '1GB'
numberOfVolumes=91
totalCapacityInGB=387
totalCapacityPercentageToStorageDomain=5
usedCapacityInGB=29
usedCapacityPercentage=8
freeCapacityInGB=358
freeCapacityPercentage=92
numberOfManagedVolumes=25
totalManagedCapacityInGB=1,000
usedManagedCapacityInGB=300
usedManagedCapacityPercentage=30
freeManagedCapacityInGB=700
freeManagedCapacityPercentage=70
consumedCapacityInGB=500
description=
cost=USD3000/TB/Year
chargefor=Allocated
thpcost=USD3/GB/Year
thpchargefor=Consumed
An instance of StorageTier(2 of 2)
name=MyStorageTier
filterCondition=RAIDLevel <> 'RAID5(3D+1P)'
numberOfVolumes=2
totalCapacityInGB=9
totalCapacityPercentageToStorageDomain=1
usedCapacityInGB=0
Details of CLI commands74