HP StorageWorks P9000 Tiered Storage Manager Software 7.1 CLI Reference Guide (TB585-96011, May 2011)

2. Use FTP or some sort of external storage media to transfer the setup file from the management
server of Tiered Storage Manager software to the management client.
You can transfer the setup file to any location, such as /tmp.
The CLI setup file is stored in the following folder or directory on the management server:
If the management server OS is Windows:
installation-folder-of-the-Tiered-Storage-Manager-server\Dist\
If the management server OS is Linux:
installation-directory-of-the-Tiered-Storage-Manager-server/Dist/
The setup file name is shown below.
TSMTiered-Storage-Manager-version-modified-version-number_E
build-number_OS-type_CLI.tar.gz
The following are the character strings that can be displayed for OS-type and their meanings:
SOL: For Solaris (SPARC)
AMD64: For Solaris (x64)
HP: For HP-UX
LNX: For Linux (RHEL)
LNXS: For Linux (SLES)
3. Unzip the transferred setup file in the /opt directory.
After the setup file is unzipped, several files are stored in the /opt directory, such as the shell
script for setup, the shell script for uninstallation, the shell script for running the CLI, and the
properties files.
4. Execute the shell script for setup (setup.sh).
/opt/TieredStorageManager/Tiered-Storage-Manager-version/Setup/setup.sh
The common library for collecting trace information is stored and set up. The common library is
stored in the following directory:
/opt/Hitachi/HNTRLib2
NOTE:
When setup.sh is executed, the following conditions will be checked. If either of the following
conditions is not satisfied, an error message will be displayed and the setup will terminate:
Whether the executed setup.sh is the same as the setup.sh that is in the path shown above
(whether the location where setup.sh will be extracted is correct)
Whether the executed setup.sh matches the management client OS
CLI Reference Guide 23