HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1 CLI Reference Guide (TB581-96066, September 2011)

DescriptionStatusParameter name
New setting for command device
Specify true to set the specified LU as a command device, and
false to release the setting.
Optional
commanddevice
Security mode setting for the command device
Specify true to enable security, and false to disable it.
Optional
command-
devicesecurity
Parameter values to obtain in advance
serialnum and model: Obtain these values from the execution result of the GetStorageArray
command. In the execution result, use the arrayType value or the displayArrayType value to
specify the model parameter, and use the serialNumber value to specify the serialnum parameter.
devnum: Obtain this value from the execution result of the GetStorageArray
(subtarget=LogicalUnit) command. Execute this command by specifying only the model and
serialnum parameters, and LogicalUnit for the subtarget parameter. In the execution result
of this command, the devNum value appears under An instance of LogicalUnit. Use this
devNum value to specify the devnum parameter.
Command execution example
hdvmcli ModifyLogicalUnit -o "D:\logs\ModifyLogicalUnit.log"
"serialnum=10001" "model=XP1024" "devnum=1" "commanddevice=true"
Command execution result
RESPONSE:
An instance of StorageArray
.
. (Attributes of StorageArray are omitted here)
.
List of 1 Lu elements:
An instance of LogicalUnit
objectID=*****
devNum=1
displayName=00:01
emulation=OPEN-3
devCount=1
devType=CommandDevice
capacityInKB=2,403,360
path=true
commandDevice=true
commandDeviceEx=1
commandDeviceSecurity=true
chassis=1
arrayGroup=0
arrayGroupName=1-1-1
raidType=RAID5(3D+1P)
currentPortController=-1
defaultPortController=-1
Command reference170