HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 Installation and Configuration Guide (TB581-96048, May 2011)
When the installation completes, the result is written in the HInstReport.txt file in the /tmp
directory. If you see SUCCESS in the summary section of the file, the installation was successful.
Related topics
• Verifying server installation conditions, page 15
• P9000 Command View AE Software server installation prerequisites, page 21
• P9000 Command View AE Software server unattended installation properties and settings, page 63
• Post-installation tasks (new installation), page 32
• Post-installation tasks (overwrite or upgrade), page 37
Performing a Device Manager agent unattended installation
You can automate agent installation by creating and executing a script file. Unattended installation
can be used when installing on multiple hosts with the same conditions. By creating a settings file
(HDVMAgent.conf), you can also perform basic setup functions during the unattended installation.
When setting up an unattended installation, note that the Device Manager agent cannot be
automatically registered as a Windows Firewall exception.
Prerequisites for Device Manager agent unattended installation
Before performing an unintended installation of the Device Manager agent, verify the host requirements
and system prerequisites and set up the installation machine. You must have the Device Manager
agent installation folder ready for the new installation and configure the settings for basic setup by
editing the HDVMAgent.conf file to provide basic setup values that are accessed during the
unattended installation.
The HDVMAgent.conf file is stored in the following location:
• In Windows: DVD-drive:\AGENTS\HDVM\Windows\HDVMAgent.conf
• In UNIX: DVD-ROM-mount-directory/AGENTS/HDVM/platform-name/HDVMAgent.conf
NOTE:
If HDVMAgent.conf is stored on a write-protected medium such as an installation DVD, copy the
directory that contains the file to a writable location and edit HDVMAgent.conf.
If a property is not specified, the default value is used. Table 20 shows these default values.
Table 20 Data set in HDVMAgent.conf
Default valueDetailsProperty Name
None
Specify the IP address or host name of the Device
Manager server.
serverIP (required)
2001Specify the port number of the Device Manager server.serverPort (required)
Installation and Configuration Guide 67