HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 Installation and Configuration Guide (TB581-96048, May 2011)

kernel-parameter-value-to-be-set =
Max{
Max {
value-that-is-enabled-in-the-system
,
initial-value-of-the-OS
}
+ value-for-Common-Component
+ value-for-Device-Manager
+ value-for-Tiered-Storage-Manager
+ value-for-Replication-Manager
,
value-for-HiRDB
}
NOTE:
Max {x, y, z} indicates the maximum value among x, y, and z.
Related topics
Setting kernel parameters and shell restrictions (Linux), page 22
Recommended Red Hat Enterprise Linux /etc/security/limits.conf values, page 25
Modifying kernel parameter values and shell restrictions, page 30
Recommended Red Hat Enterprise Linux /etc/security/limits.conf values
Before installing P9000 Command View AE Software on a Red Hat Enterprise Linux system, set the
shell restriction values for the /etc/security/limits.conf file. Set the shell restrictions for both
soft and hard settings.
NOTE:
The soft value must be less than or equal to the hard value.
The appropriate values for each of these settings depend on which of the following P9000 Command
View AE Software products you are installing:
Common Component
Device Manager
Tiered Storage Manager Software
Replication Manager Software
Installation and Configuration Guide 25