HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)
DescriptionAttribute
Component where the alert occurred
For details about the component, see the attribute name of the instance
Component.
component
Alert description (example: Serious error detected on DKU drive.)description
Action to be taken for the alert (example: Contact Customer Support.)actionToTake
Data required to analyze the alert
When the value of type is Trap, the SIM data required by the customer service
is output.
data
Time at which the alert occurred (example: 2008/04/06 20:13:56)timeOfAlert
ArrayGroup instance
The ArrayGroup instance is output when the following commands are executed:
• “AddExternalArrayGroup” on page 42
• “AddPool” on page 65
• “AddVirtualVolume” on page 76
• “GetStorageArray (subtarget=ArrayGroup) ” on page 111
• “GetStorageArray (subtarget=FreeSpace) ” on page 122
• “GetStorageArray (subtarget=PDEV) ” on page 147
• “GetStorageArray (subtarget=Pool) ” on page 149
• “ModifyPool” on page 170
Table 104 ArrayGroup instance attributes
DescriptionAttribute
Object ID of the parity group
objectID
Parity group name
This item is output if it has been registered.
name
Number of the chassis containing the parity group
chassis
Parity group number
number
Display name of the parity group (example: 1, 1-1, 2-1-1, S3-1)
S in the above format indicates the type of the parity group.
• E: Parity group of an External volume
• V: Parity group of V-VOL
• X: Parity group of a volume for Thin Provisioning Software
displayName
CLI Reference Guide 281