HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 Administrator Guide (web) (TB581-96050, May 2011)

Device Manager agent requirements for managing copy pairs
If you use the GUI to operate copy pairs, the required version of the Device Manager agent differs
depending on the storage system used.
Table 8 Device Manager agent requirements for managing copy pairs by using the GUI
Device Manager agent versionStorage system
7.0 or laterP9500
6.0 or later
XP24000/XP20000
XP12000/XP10000/SVS200
If you use the CLI to operate copy pairs, the required version of the Device Manager agent differs
depending on the program, operation, and storage system model to be used.
Table 9 Device Manager agent requirements for managing copy pairs by using the CLI
Device Manager agent
version
#
Operation from Device ManagerProgram
1.1 or laterDisplay the status
Continuous Access Journal
5.5 or laterDisplay the status (3DR)
5.6 or laterChange the status
5.5 or laterChange the status (3DR)
1.0 or laterDisplay the status
Continuous Access
1.0 or laterChange the status
1.0 or laterDisplay the status
Business Copy
1.0 or laterChange the status
1.0 or laterDisplay the statusSnapshot
Note:
To create a configuration definition file, Device Manager agent version 3.1 or later must be in-
stalled on each host.
#:
The following table lists the Device Manager agent version required for each storage system
model.
Table 10 Device Manager agent version required for each storage system model when managing
copy pairs by using the CLI
Device Manager agent versionStorage system model
7.0 or laterP9500
5.7 or laterXP24000
5.8 or laterXP20000
Administrator Guide (Web Version) 53