HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 Administrator Guide (web) (TB581-96050, May 2011)

Specify root/smis/smisxx (xx is an abbreviation for the version number).
For example, to specify version 1.5.0, enter root/smis/smis15.
The latest namespaces that complies with the specified SMI-S version is selected.
Specify the condition current.
Enter root/smis/current.
The current namespace is selected.
Specify interop.
SMI-S 1.3.0 or a later version supports the namespace interop. If interop is specified as the
namespace, the Server profile that stores the current management server information is specified.
The namespace of each vendor is accessed via this Server profile to obtain information about the
Array profile and its subprofiles.
CAUTION:
If you need to specify the namespace dmxx (xx is an abbreviation for the version number) that was
supported by Device Manager 5.8 or earlier versions, contact maintenance personnel.
The following table describes the correspondence between the namespaces supported by Device
Manager and SMI-S versions.
Table 47 Correspondence between namespaces and SMI-S versions
SMI-S
Namespace
interopcurrent
smisxx
1.1.0----
smis11
1.2.0----
smis12
1.3.0----
smis13
1.4.0----
smis14
1.5.0interopcurrent
smis15
Legend: --: N/A
You can obtain information about CIM at:
http://www.dmtf.org/home/
You can obtain information about SMI-S at:
http://www.snia.org/smi/home/
CIM/WBEM features of Device Manager
CIM/WBEM of Device Manager provides the four features specified in SMI-S:
Objection operation feature
Indication feature
Service discovery feature
Settings for CIM/WBEM138