HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 Administrator Guide (web) (TB581-96050, May 2011)
Settings required to output SNMP traps to log files
To set up Device Manager to receive SNMP traps and output them to log files, the following settings
must be specified:
• Settings required for Device Manager to receive SNMP traps
• Device Manager must be able to use port 162/tcp of the management server.
• The management server information must be registered in SNMP related software as the target
for trap notification.
For example, to receive storage system SNMP traps, SNMP Agent settings must be specified.
• Specify true for the server.dispatcher.daemon.receiveTrap property.
• Settings required to output received SNMP traps to log files
• Specify true for the customizedsnmptrap.customizedSNMPTrapEnable property.
• The output contents must be set in the customizedsnmptrap.customizelist property.
Setting the data to be output to log files
By using the customizedsnmptrap.customizelist property, you can specify the severity and
output format of SNMP traps to be recorded in log files.
Specify the items shown in the following table by separating them using a colon (:).
Table 42 Items specified in the customizedsnmptrap.customizelist property
RemarksFormatItem
Required
Specify by using dots (for example,
.1.3.6.1.4.116.3.11.1.2)
enterprise-
ID
RequiredNumeric value, from 0 to 6
generic-
trap-number
RequiredNumeric value
specific-
trap-number
This item is optional. If you omit this item, Null
is assumed.
The severity indicators in the message IDs are
output as follows:
• -I for Information
• -W for Warning
• -E for Error, Critical, and Alert
• No log data is output for Null
Specify the severity of each trap by using
one of the character strings below.
You cannot use character strings other
than the following:
• Information
• Warning
• Error
• Critical
• Alert
• Null
severity
Administrator Guide (Web Version) 127