HP P9000 Command View Advanced Edition Suite Software 7.4.1-03 Release Notes (TB581-96357, May 2013)

If the security of any WWN is removed from a host group, execute the
DeleteWWNForHostStorageDomain CLI command.
Displaying information on Plug-in for Virtualization Server Provisioning and VMware
vSphere Client
Some information on a datastore or a virtualization server displayed on the Plug-in for Virtualization
Server Provisioning might be different from the information displayed on the VMware vSphere Client.
In this case, restart the Pegasus in the vMA, and ask a storage administrator to refresh the information
on the virtualization server that Device Manager manages.
Loading a window of the Plug-in for Virtualization Server Provisioning
A dialog box with the message Are you sure you want to navigate away from this
page? might be displayed while the Plug-in for Virtualization Server Provisioning is used.
If this occurs, click the Cancel button on the dialog box.
Meter-based Term License
When only the Meter-based Term license is registered, an Emergency license cannot be input.
Changing the hostname
If one or more letters in the target host name is changed, after host information is refreshed, the HiScan
command is executed or the Device Manager agent service is restarted on a host, pair information
may not be managed by the host.
To change the host name, perform the following:
1. Stop the Device Manager agent service and automatic execution of the HiScan command on
the host.
2. Check whether the target host is registered in any resource groups.
3. Change the target host name.
4. From the Device Manager GUI or CLI, change the host name to a completely different name.
Example:
Before: ABCD
After: EFGH
5. Start the Device Manager agent service and automatic execution of the HiScan command on
the host.
6. From the Device Manager GUI or CLI, delete the host name in the Device Manager server.
7. If the target host had been registered in any resource groups (as described in step 2), register the
host again.
8. Refresh the storage systems to which the LUNs recognized by the target host belong.
The parity group list dialog
The parity group number might not be displayed correctly.
In this case, please refer to the parity group summary information to confirm the correct number.
In addition, the format type cannot be chosen when the create volume dialog is opened from the parity
group list.
Open the dialog from another screen.
18 Important considerations