HP P9000 Command View Advanced Edition Suite Software 7.4.0-00 CLI Reference Guide (TB581-96326, December 2012)

Table Of Contents
hdvmcli GetStorageArray -o "D:\logs\GetStorageArray_TieringPolicy.log"
subtarget=TieringPolicy model=P9500 serialnum=53039 policyid=10
Command execution result
RESPONSE:
An instance of StorageArray
.
. (Attributes of StorageArray are omitted here)
.
List of 1 TieringPolicy elements:
An instance of TieringPolicy
objectID=*****
policyID=10
allocationThresholdT1Max=50
allocationThresholdT1Min=20
allocationThresholdT3Max=40
allocationThresholdT3Min=10
numberOfVVols=4
*****: The values are encoded by the CLI.
GetTieredPoolStatus
GetTieredPoolStatus obtains the execution status of performance monitoring and hardware tier
relocation for a Smart pool executed by using the AddTieredPoolOperation command.
NOTE:
This command can be used only with P9500.
Table 64 GetTieredPoolStatus command parameters
DescriptionStatusParameter name
Serial number of the storage systemRequired
serialnum
Model of the storage systemRequired
model
List of pool IDs
Specify the pool ID of a Smart pool.
Use a comma to delimit multiple values.
The maximum number of pool IDs that can be specified is 128.
Required
poolids
Parameter values to obtain in advance
serialnum and model
Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
Command reference182