HP P9000 Command View Advanced Edition Suite Software 7.3.1-00 Administrator Guide (web)

Table Of Contents
DescriptionPort number
Used for SSL communication with management clients (via the GUI or the CLI).
You can change the port by modifying the server.rmi.security.port
property in the server.properties file of the Tiered Storage Manager server.
24500/tcp
Ports used by Host Data Collector
The following table describes the ports used by Host Data Collector.
Table 15 Ports used by Host Data Collector
DescriptionPort number
Used for SSH communication with a management-target normal host running UNIX.22/tcp
Used internally for Host Data Collector communication.23050/tcp
Used for non-SSL communication between the Device Manager server and a Web
server.
23051/tcp
Used internally for Host Data Collector communication.23052/tcp
Used for non-SSL communication between the Device Manager server and the RMI
registry when Host Data Collector is installed on a Windows computer.
You can change the port by using the hdc.common.rmi.registryPort
property in the hdcbase.properties file of Host Data Collector.
22098/tcp
Used for non-SSL communication between the Device Manager server and the RMI
server when Host Data Collector is installed on a Windows computer.
You can change the port by using the hdc.common.rmi.serverPort property
in the hdcbase.properties file of Host Data Collector.
22099/tcp
Used for non-SSL communication between the Device Manager server and the
class loader when Host Data Collector is installed on a Windows computer.
You can change the port by using the hdc.common.http.serverPort property
in the hdcbase.properties file of Host Data Collector.
22100/tcp
Used for SSL communication between the Device Manager server and the RMI
registry when Host Data Collector is installed on a Windows computer.
You can change the port by using the hdc.common.rmi.ssl.registryPort
property in the hdcbase.properties file of Host Data Collector.
22104/tcp
Used for SSL communication between the Device Manager server and the RMI
server when Host Data Collector is installed on a Windows computer.
You can change the port by using the hdc.common.rmi.ssl.serverPort
property in the hdcbase.properties file of Host Data Collector.
22105/tcp
Used for SSL communication between the Device Manager server and the class
loader when Host Data Collector is installed on a Windows computer.
You can change the port by using the hdc.common.https.serverPort
property in the hdcbase.properties file of Host Data Collector.
22106/tcp
Network configuration76