HP P9000 Command View Advanced Edition Suite Software 7.3.1-00 Administrator Guide (web)

Table Of Contents
The value that can be specified for MU# differs depending on the version and copy type of the
Device Manager agent, as shown below.
When the version of the Device Manager agent is 6.0 or later:
Business Copy: 0 to 2
Snapshot: 0 to 63
Continuous Access: Not specified
XP24000/XP20000: 0
#
, h1, h2, or h3
#:
When specified, multi-target configuration pairs cannot be created with Continuous Access.
When the version of the Device Manager agent is 5.9 or earlier:
Business Copy: 0 to 2
Snapshot: 0 to 31
Continuous Access: Not specified
XP24000/XP20000: h1, h2, or h3
HORCM_INST parameter
The following explains the description rules related to dev_group, ip_address, and service.
Specify dev_group using no more than 31 single-byte characters. A hyphen (-) cannot be spe-
cified at the beginning of the character string.
You cannot specify ip_address more than once for the same host for a single dev_group.
For ip_address, specify the information for the host managed by the Device Manager server.
The host name specified for ip_address is case sensitive.
Match the IP address version (IPv6 or IPv4) specified for ip_address to the one specified for
HORCM_MON.
When an IPv6 environment is being used, you cannot specify a host name. If you specify a host
name, an IPv4 environment is used.
Some of the items in the following table cannot be used to determine the host. As such, they cannot
be specified for ip_address.
Table 97 Values that cannot be specified for the ip_address of HORCM_INST parameter
Device Manager agent version
Value
05-70 or earlier05-80 or later
YesYesIP address
YesYesHost name
NoSometimes
Loopback IP addresses (127.0.0.1 to
127.255.255.254)
NoSometimes
Loopback host name (localhost)
NoNoCluster virtual IP address
NoNoCluster virtual machine name
Legend:
Yes: Can be specified.
Administrator Guide (Web Version) 243