HP P9000 Command View Advanced Edition Suite Software 7.2 Administrator Guide (web)

The alerts that Device Manager can monitor differ by storage system. The following table lists the
alerts that can be monitored by different storage systems.
Table 42 Alerts that can be monitored by Device Manager
SNMP trapsStorage system site statusManagement target
YYP9500
Storage system
YYXP24000/XP20000
YYXP12000/XP10000/SVS200
YYXP1024/XP128
----
SMI-S Enabled storage
systems
Legend
Y: Supported
--: Not supported
Required settings for receiving SNMP traps
The following settings must be specified so that Device Manager receives SNMP traps output by
storage systems:
Device Manager must be able to use port 162/udp of the management server.
The IP address of the management server must be registered in the SNMP Agent settings for storage
systems as a target for trap notification.
Specify true for the server.dispatcher.daemon.receiveTrap property.
Receiving email alerts
You can set up Device Manager to automatically send the content of alerts to users by email. This
enables users to be aware of failures that have occurred in storage systems without logging in to the
management client.
The settings required for sending alerts to users by email are described below.
Setting up logs and alerts122