HP P9000 Command View Advaced Edition Software Update 7.2.0-02 Release Notes (TB581-96305, March 2012)
Parity groups which can be searched using Keyword Search are in the following storage systems.
• P9500
• XP24000/XP20000
• XP12000/XP10000/SVS200
Parity groups in storage systems other than the above cannot be searched using Keyword Search.
Volume search:
Search results might not be correct if is not is specified as a conditional equation in volume search by
label. Only volumes assigned labels can be searched.
In this case, sort the volumes by the Label column after filtering candidate volumes by attributes other
than Label.
Create Volumes dialog box
• When volumes are created in an XP12000/XP10000/SVS200 system, an LDEV ID cannot be
specified manually in the Create Volumes dialog box. If an LDEV ID that is 3F:01 or more values
is specified, the KAIC15306-W message appears. Use the CLI AddLogicalUnit command to
create volumes with LDEV IDs that are 3F:01 or more values.
When an LDEV ID is assigned automatically, this issue does not occur.
• While the KAIC15306-E error is occurring in the Create Volumes dialog box, even if the Initial
LDEV ID is changed, the Show Plan button cannot be enabled and the plan cannot appear.
If this occurs, open the Create Volumes dialog box again.
Editing pool name
In the editing pool dialog box, a backquote (`) can not be used in the Pool Name text field. If you
click the Show Plan button with a backquote in the Pool Name text field, the KAIC16993–E error
occurs.
If this occurs, remove the backquotes from the Pool Name text field.
Displaying capacity of hosts
When the capacity of hosts is changed by Create LUSE Volumes or Expand THP Volumes, the capacity
of hosts is not refreshed.
Refresh the hosts or the storage systems to display the latest capacity of hosts.
Status of data collection tasks
If the progress indicator of the following tasks is 100%, the status column in the Data Collection Tasks
tab of the Administration tab might still be In Progress:
• Add Storage Systems
• Refresh Storage Systems
• Remove Storage Systems
To confirm the actual status of the tasks above, check the status column of the Storage Systems table
by opening the data collection task detail dialog box of the task.
The logical group information also is not updated.
To confirm the last logical group information, wait for the status column of Data Collection Tasks tab
to be Completed.