HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)

Explanation and recommended actionsMessage textMessage ID
No copy pair information was acquired from the volume to which the
device number Devn was assigned because no I/O paths are
available.
Verify the I/O path settings.
Devn
The device number of the volume on which information acquisition
was skipped
No I/O paths are available for the
specified devices. DEVN=Devn
YKH201W TSO
A P-VOL not defined in the disk configuration definition file was included
among the PPRC copy pairs detected by the YKH2B command.
Check whether this P-VOL is defined in the disk configuration definition
file.
Devn
The device number of the detected undefined volume
SerialNum
The storage system serial number of the detected undefined volume
CU#
The control unit number of the detected undefined volume
CCA#
The command control address number of the detected undefined
volume
Unable to resolve primary volume
information.
DEVN=Devn,SN=Serial-
Num,CU=CU#,CCA=CCA#
YKH202W TSO
An S-VOL not defined in the disk configuration definition file was
included among the PPRC copy pairs detected by the YKH2B command.
Check whether the detected S-VOL is defined in the disk configuration
definition file.
SerialNum
The storage system serial number of the detected undefined volume
CU#
The control unit number of the detected undefined volume
CCA#
The command control address number of the detected undefined
volume
Unable to resolve secondary volume
information. SN=Serial-
Num,CU=CU#,CCA=CCA#
YKH203W TSO
A dynamic change was detected in an I/O configuration definition
when the YKH2B command was executed either without the HS
parameter or with HS(CHECK).
Check the status of the device targeted by the YKH2B command, correct
any errors in the configuration or execution conditions (such as the
parameter setting or the times at which the command has been
executed), and then re-execute the command.
device-number
Device number being processed when a dynamic change was
detected in an I/O configuration definition
A dynamic configuration change was
detected. DEVN=device-number
YKH204W TSO