HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)

Explanation and recommended actionsMessage textMessage ID
The internal routine encountered a shortage of work space.
Contact Technical Support for assistance.
file
Name of the configuration file where the error was detected
rec#
Number of the line in the file identified by file where the error
was detected
The element stack was overflowed.
YKG295E MSG
SC=44 RC=44
(file:rec#)
An unexpected error has occurred.
This error might have occurred with another error.
If another error message was output at the same time as this one, follow
the instructions in that message to fix the corresponding problem.
If no other error message was output, collect the following materials
and contact your HP Technical Support or authorized service provider:
The script from which this command was executed (not necessary
if this command was executed from the ISPF panel).
The ISPF log (not necessary if this command was executed from
a script).
The definition files operated on from the script or ISPF panel (the
copy group definition file, disk configuration definition file, com-
mand device definition file and route list definition file).
detailed-info
Information displayed to assist the HP Technical Support or author-
ized service provider in resolving the problem.
YKGETHDA encountered an unexpec-
ted error.
YKG298E MSG TSO
SC=44 RC=44 (de-
tailed-info)
The YKH2B command terminated.
return-code
Return code of the YKH2B command:
0: The command ended successfully. One or more copy group
definition file was created.
4: One of the following occurred:
- The command ended successfully. No copy pairs were detected
within the range of the specified device numbers.
- A copy group definition file was created, but volume information
not defined in the disk configuration definition file for the site
specified in the DAD parameter was detected among copy pairs
within the range specified in the DEVN parameter.
- A copy group definition file was created, but a change was de-
tected in the I/O configuration when the YKH2B command was
executed without specifying the HS parameter or the YKH2B
command was executed by specifying HS(CHECK).
- A copy group definition file was created, but a storage system
that does not support 2DC configuration with HyperSwap and
Continuous Access Journal was detected.
8: An I/O error occurred with a volume within the scan range.
Copy group definition files were created for the volumes that were
successfully detected.
44: The processing was canceled due to an error. The copy group
definition file was not created.
48: The command ended due to an invalid parameter.
YKH2B completed. RC=return-
code
YKH001I TSO