HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)

Explanation and recommended actionsMessage textMessage ID
The IRXTERM routine returned an error with the return code identified
by return-code. BCM Monitor will stop.
Check the return code.
return-code
For details about the return code, see TSO/E REXX Reference.
abnormal-termination-code-and-reason-code-for-abnor-
mal-termination
R0 includes the abnormal termination code and the reason code
for abnormal termination. IRXTERM returns the abnormal termin-
ation code in the two trailing bytes of R0 and returns the reason
code for abnormal termination in the two leading bytes of R0. If
the reason code for abnormal termination is larger than two bytes,
IRXTERM returns only the two trailing bytes of the reason code
for abnormal termination. For details about the abnormal termina-
tion code and reason code, see MVS System Codes.
IRXTERM module error: code=re-
turn-code,R0=abnormal-ter-
mination-code-and-reason-
code-for-abnormal-termina-
tion.
YK8027E CON
The main task or subtask terminated abnormally during BCM Monitor
processing. If the task cannot be recovered, BCM Monitor will stop.
Contact the center administrator.
Sxxx (hexadecimal number)
System completion code when the task terminated abnormally
Uxxxx (decimal number)
User completion code when the task terminated abnormally
module-name
Section name of the BCM Monitor module or load module name.
If the module cannot be identified, UNKNOWN is displayed. In this
case, the values of y'y'.m'm'.d'd' and bbbbbbbb are invalid.
module-creation-date
This is displayed in one of the following formats:
y'y'.m'm'.d'd': Creation date of the module identified by
module-name
y'y'/m'm'/d'd': Creation date of the module identified by
module-name
bbbbbbbb
Contents of the base register
dddd
ABENDED-MODULE: Location where ABENDED-MODULE was
called, relative to the top of the module
CALLING-MODULE: Location where CALLING-MODULE was
called, relative to the top of the module
pppppppp pppppppp
PSW during the abnormal termination
ll
Length of the command during the abnormal termination
xx
Interrupt code during the abnormal termination
BCM Monitor function abend:
code=Sxxx Uxxxx
abended-module=module-name
C-Date=module-creation-date
base=bbbbbbbb disp=dddd
[calling-module=module-name
C-Date=y'y'.m'm'.d'd'
base=bbbbbbbb disp=dddd]
PSW=pppppppp pppppppp
ILC=ll INTC=xx
Registers at time of failure
GR 00-03
contents-of-register-0
contents-of-register-1
contents-of-register-2
contents-of-register-3
GR 04-07
contents-of-register-4
contents-of-register-5
contents-of-register-6
contents-of-register-7
GR 08-11
contents-of-register-8
contents-of-register-9
contents-of-register-10
contents-of-register-11
GR 12-15
contents-of-register-12
contents-of-register-13
contents-of-register-14
contents-of-register-15
YK8028E CON
Messages56