HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)
Table Of Contents

Explanation and recommended actionsMessage textMessage ID
YKBTSCAN terminated with the return code nnnn. This message is
always displayed to indicate the return code.
nnnn
Maximum value among the output return codes
YKBTSCAN return code=nnnn
YK7099I PRT
BCM Monitor has started.
v.r.m-nn
Version and revision number
BCM Monitor started. (v.r.m-nn)
YK8001I CON
BCM Monitor has stopped.BCM Monitor terminated.YK8002I CON
BCM Monitor set the monitoring status of all copy groups to INACTIVE.
time
Message output time
This is only displayed when the output destination is SYSTSPRT.
time BCM Monitor stopped monitor-
ing Copy Groups.
YK8003I PRT CON
The copy progress percentage for the copy group identified by cgid
is decreasing.
time
Message output time
This is only displayed when the output destination is SYSTSPRT.
cgid
Copy group ID
time Synchronization percentage
decreased, Copy Group: cgid.
YK8007I PRT CON
An attempt to start BCM Monitor failed because of the reason indicated
in a preceding message that was output to either the console or dd
SYSTSPRT.
Contact the center administrator. If you are the center administrator,
take action that is appropriate to the previously output message, and
then restart BCM Monitor.
termination-code (decimal number)
• 04: An attempt was made to start BCM Monitor without using
IKJEFT01.
• 20: An attempt to analyze the YKMONOPT file failed.
• 24: An attempt to analyze the YKMONCG file failed.
• 32: An error occurred while loading the process module.
• 36: No profile is defined in the FACILITY class of RACF.
• 40: The prefix specified in the YKMONCG file is being used by
the Business Continuity Manager agent.
• 44: An attempt to initialize the subtask failed.
BCM Monitor initialization failed:
termination-code.
YK8008E CON
The task terminated abnormally during startup of BCM Monitor. BCM
Monitor will stop.
task-ID
Name for identifying the task
completion-code
System completion code
Task(task-ID) abended: comple-
tion-code.
YK8009E CON
Messages 53