HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)
Table Of Contents

List of messages starting with YK
The following tables list and describe messages starting with YK.
Wait until all pending commands have finished execution before taking corrective action.
Table 2 List of messages (message ID YK70x - YK90x)
Explanation and recommended actionsMessage textMessage ID
An invalid parameter was specified. Revise the value specified on the
line number identified by line.
Supplied parameters invalid: line
YK7000T PRT RC=16
The parameter parameter-name is not specified.
No parameter-name parameter
supplied.
YK7001E PRT RC=16
The value assigned to the parameter-name parameter is invalid.
Revise the value specified on the line number identified by line.
The parameter parameter-name
is invalid: line
YK7003E PRT RC=16
The value assigned to the parameter-name parameter is invalid.
The parameter parameter-name
is invalid.
YK7004E PRT RC=16
The command indicated by command was issued, and ended with the
return code rc.
RC: rc CMD: command
YK7014I PRT
The command indicated by command was issued, and ended with the
return code rc.
Severity
Severity code stored in Severity for the message structure
Text
Message ID and message text stored in Text for the message
structure
Value
Detailed information stored in Value for the message structure
Severity: Severity, Text: Text, and Value: Value are
displayed an amount of times equal to the number of messages included
in the message structure.
RC: rc CMD: command
Severity: Severity
Text: Text
Value: Value
YK7015I PRT
The number of devices scanned by executing YKBTSCAN.
count
Number of scanned devices
Scanned DASD Device Count:
count
YK7031I PRT RC=0
The number of HP storage-system devices scanned by executing
YKBTSCAN.
count
Number of scanned HP storage-system devices
HP storage systems Devices Found:
count
YK7032I PRT RC=0
As a result of a scan, information acquisition was skipped for the
devices on which no I/O paths were available.
count
Number of devices for which information acquisition was skipped
The specified devices that do not
have any available I/O paths were
skipped: count
YK7033I PRT RC=4
Messages52