HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)
Table Of Contents

DescriptionMessage textMessage ID
Core processing ended.
process (character string)
Process name
yyyy/mm/dd (character string)
GMT date
hh:mm:ss.th (character string)
GMT time
ttt (character string)
Format of GMT time
xxx (decimal number)
Command code of the executed command
For details, see the command code description for
the KTZ201E message.
yyy (character string)
Maintenance information
The Core processing( process ) ended.
(DATE=yyyy/mm/dd, TIME=hh:mm:ss.th,
TOD=ttt, cmd=xxx, pos=yyy)
KTZ209I CON PRT RC=0
The command cannot be executed because a NAME/
TOKEN read error occurred.
Make sure that the KTLOAD command terminated
normally.
nnn (decimal number)
Return code set by the NAME/TOKEN read routine
(IEANTRT)
name (character string)
Name to be registered in the NAME/TOKEN service
xxx (decimal number)
Command code of the command that was being
executed when the error occurred
See the description of command codes for the
KTZ201E message.
yyy (character string)
Maintenance information
A NAME/TOKEN read error occurred. (return
code=nnn, name= name, cmd=xxx,
pos=yyy)
KTZ210E MSG TSO CON
SC=44 RC=44
The command cannot be executed because a NAME/
TOKEN write error occurred.
nnn (decimal number)
Return code set by the NAME/TOKEN registration
routine (IEANTCR)
name (character string)
Name to be registered in the NAME/TOKEN service
xxx (decimal number)
Command code of the command that was being
executed when the error occurred
See the description of command codes for the
KTZ201E message.
yyy (character string)
Maintenance information
A NAME/TOKEN write error occurred. (return
code=nnn, name= name, cmd=xxx,
pos=yyy)
KTZ211E MSG CON
SC=44 RC=44
Messages48