HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)

Type of error
Error details
Error
code
OtherSMARTPATHCMDCAJCAACABC
NNNNYNNN
A CAJ copy pair status cannot be changed be-
cause the specified serial number or SSID of the
primary storage system does not match the actual
serial number or SSID of the primary storage sys-
tem.
EB3C
NNNNYNNN
A CAJ copy pair status cannot be changed be-
cause the specified serial number or SSID of the
secondary storage system does not match the ac-
tual serial number or SSID of the secondary storage
system.
EB3D
NNNNYNNN
A delta resync pair cannot be made. The reason
might be one of the following:
The P-VOL of a CA copy pair and another P-
VOL of a CAJ copy pair do not match.
The storage system serial number on the copy
source is incorrect.
EB48
NNNNYNNN
A delta resync pair cannot be made because the
delta resync function is not supported in the RCU.
EB49
NNNNYNNN
A CAJ copy pair cannot be made because the
specified R-JNL group is not registered.
EB4C
NNNNYNNN
A CAJ copy pair cannot be made because the
specified M-JNL group is not registered in the
storage system.
EB4D
NNNNYNNN
A CAJ copy pair cannot be made because the
timer type for M-JNLG differs from that for R-JNLG.
EB4F
NNNNYNNN
A CAJ copy pair cannot be made because the
specified volume does not exist.
EB50
NNNNYNNN
A CAJ copy pair cannot be made because the
specified S-VOL has PIN data.
EB51
NNNNYNNN
A CAJ copy pair cannot be made because the
specified S-VOL cannot be accessed.
EB52
NNNNYNNN
A CAJ copy pair cannot be made because the
specified S-VOL is blocked.
EB53
NNNNYNNN
A CAJ copy pair cannot be made because the
status of the cache is abnormal.
EB56
NNNNYNNN
A CAJ copy pair cannot be made because the
LDEV guard is set for the specified P-VOL or S-VOL.
EB5B
NNNNYNNN
A CAJ copy pair cannot be made because the
LDEV security is set for the specified P-VOL or S-
VOL.
EB5D
Storage system sense byte information286