HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)
Table Of Contents

Type of error
Error details
Error
code
OtherSMARTPATHCMDCAJCAACABC
NNNNYNNN
A CAJ copy pair cannot be made because the
charging limit of CA in the RCU has been ex-
ceeded. Check the license capacity of this and all
related program products.
EAA3
NNNNYNNN
A CAJ copy pair cannot be made because the
charging limit of CAJ in the RCU has been ex-
ceeded. Check the license capacity of this and all
related program products.
EAA5
NNNNYNNN
A CAJ copy pair cannot be made because the
charging limit of CA in the MCU has been ex-
ceeded. Check the license capacity of this and all
related program products.
EAA6
NNNNYNNN
A CAJ copy pair cannot be made because shared
memory is not implemented for the specified LDEV
number.
EABC
NNNNYNNN
A CAJ copy pair cannot be made with the HOLD
parameter specified because the micro does not
support the delta resync function.
EAD0
NNNNYNNN
A copy pair cannot be created because the THPz
volume specified for the P-VOL of a CAJ copy pair
is being expanded.
EAE5
NNNNYNNN
A CAJ copy pair cannot be dissolved because
mode 707 of a storage system option is ON and
the specified volume is part of a CA copy pair.
EAE7
NNNNYNNN
A CAJ copy pair could not be made with the HOLD
parameter, or a CAJ copy pair could not be resyn-
chronized because the copy pair was in a status
for which status transition could not be performed.
EAF6
Table 67 Details of error codes EBxx
Type of error
Error details
Error
code
OtherSMARTPATHCMDCAJCAACABC
NNNNYNNN
A CAJ copy pair status cannot be changed be-
cause the specified journal group number is inval-
id.
EB02
NNNNYNNN
Registration to or deletion from EXCTG has failed
because the micro is being replaced, or there are
intermixed micros which do not support 4x4 con-
figuration.
EB08
NNNNYNNN
Registration to or deletion from EXCTG has failed
because the entered parameter was incorrect.
EB09
Storage system sense byte information284