HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)

DescriptionMessage textMessage ID
An I/O error occurred. This device was skipped and
processing continued.
If sense byte information has been set, the KTH255E
message displays the sense byte information.
For CC=3:
The indicated device might not have been installed
or might not have been connected.
For CC=0 and CSW=nnnnnn0000nnnn (DSB=00 and
CSB=00) where n indicates a value:
The indicated device might not have been installed
or might not have been connected.
For CC=0 and CSW=0000000006nnnn where n indic-
ates a value:
An MIH occurred or a logical path might not have
been connected.
device-number-1 (character string)
Device that issued an I/O
device-number-2 (character string)
Operation-target device
If the device number of the operation-target device
is not found, **** is displayed.
code-1 (decimal number)
CC information (one digit)
code-2 (hexadecimal number)
CSW information (14 digits)
code-3 (hexadecimal number)
Subcommand code (4 digits)
code-4 (hexadecimal number)
Completion code (2 digits)
code-5 (hexadecimal number)
Details code (2 digits)
xxx (decimal number)
Command code of the command that was being
executed when the error occurred
See the description of command codes for the
KTZ201E message.
yyy (character string)
Maintenance information
volume-ID
Information that identifies the volume in which the
error occurred
Volume serial number, control unit number, and
command control address number
DASD device device-number-1(device-
number-2) I/O error. (CC=code-1
CSW=code-2 code-3 code-4 code-5,
cmd=xxx, pos=yyy)
KTH253E MSG TSO SC=32
RC=32 (volume-ID)