HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)

Type of error
Error details
Error
code
OtherSMARTPATHCMDCAJCAACABC
NNNNNYYN
A CA or CAA copy pair cannot be dissolved.
Possible reasons include one or more of the
following:
It is already in the SIMPLEX status.
The P-VOL in the parameter and the bootup
volume number do not match.
The S-VOL number in the parameter is incor-
rect.
The serial number or SSID of the primary
storage system in the parameter does not
match the storage system serial number or
SSID of the local CU.
The serial number of the secondary storage
system or SSID in the parameter does not
match the storage system serial number or
SSID of RCU.
The S-VOL number in the parameter and
bootup volume number do not match.
The status of the copy pair is invalid.
The status of the copy pair is being changed.
8D5A
NNNNNNNY
A BC copy pair cannot be dissolved. Possible
reasons include one or more of the following:
The status of the copy pair does not allow the
status transition. For details, see error code
2310.
The copy pair is in the V-Split status.
The specified C/T group ID is not registered.
8D5B
YNNNNNNNThe host command parameter is incorrect.
8D70
NNNNNYNN
A CAA C/T group cannot be registered or
changed. Possible reasons include one or more of
the following:
The specified C/T group ID is incorrect.
You cannot specify System as the timer type.
The timer type is incorrect (not System,
Local or None).
The C/T group ID is already registered.
The C/T group ID is not registered.
The timer type (System, Local, or None)
cannot be changed because there is a copy
pair in the specified C/T group.
There is a copy pair in the corresponding
C/T group that has a status that is neither
SIMPLEX nor suspend.
The copy types of the specified C/T group
and the types of bootup C/T group do not
match.
8D71
Storage system sense byte information258