HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)

Type of error
Error details
Error
code
OtherSMARTPATHCMDCAJCAACABC
NNNNNYYN
A CA or CAA copy pair cannot be made or
resynchronized. Possible reasons include one or
more of the following:
The P-VOL is a command device.
The specified serial number of the primary
storage system or SSID does not match the
storage system serial number or SSID of the
local CU.
The specified P-VOL does not match the
bootup volume.
The C/T group ID is incorrect.
The P-VOL has not been made in the corres-
ponding C/T group.
The S-VOL is not in the Reverse Resync status.
Either C/T group ID or the C/T group timer
type is incorrect.
8D1C
NNNNNNNY
A BC copy pair cannot be made or
resynchronized. Possible reasons include one or
more of the following:
The S-VOL is online.
The status of the copy pair does not allow the
status transition. For details, see error code
2310.
The P-VOL is online.
The charging limit of the program product
was exceeded.
The copy pair is in the Pending status.
The copy pair is not in the Split status.
The specified C/T group ID is not registered.
The number of copy pairs in the specified
C/T group ID exceeds the maximum number.
8D1D
YNNNNNNN
The serial numbers for the primary and the second-
ary storage systems in the host command paramet-
er is incorrect.
8D1E
NNNNNYYYThe host command parameter is incorrect.
8D20
NNNYNNNN
The command cannot be executed because the
volume specified by the host command parameter
is in the NOT READY status.
8D21
NNNYNNNN
The command cannot be executed because the
logical volume of the volume specified by the host
command parameter is blocked.
8D22
NNNNNYYY
The command could not be executed because the
CA, CAA, or BC program product is not installed.
8D25
Messages 253