HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)
Table Of Contents

Explanation and recommended actionsMessage textMessage ID
You cannot use the Errorlevel attribute for this storage system.
In this case, use a device
#2
that supports the Errorlevel attribute for
Continuous Access Journal. Also, if a scan was not performed after the
storage system microcode was replaced, perform another scan.
SUPFnc (hexadecimal number)
Value for the version of the storage system support function used
in the copy group (minimum)
#1
If this message is output while the YKLOAD command is being ex-
ecuted, the RC is 44.
#2
The Errorlevel for Continuous Access Journal can be used in a
storage system where the version of the storage system support
function is X'12' or higher.
The YKSUSPND command with the ATOPT(UR) parameter specified
was executed on a copy group other than a Business Copy copy group
with the consistency group ID specified. The ATOPT(UR) parameter
is only valid on Business Copy copy groups with the consistency group
ID specified.
Re-execute the YKSUSPND command without specifying the ATOPT
parameter, or with the ATOPT(NORMAL) parameter specified.
ATOPT(UR) parameter is only valid
for BC Copy Groups with C/T ID.
YKZ411E MSG
SC=36 RC=48
The CAJ ATTIME Suspend Function is not available for this storage
system.
Use a device
#
for which the CAJ ATTIME Suspend Function is supported.
Also, if scanning was not performed after the storage system microcode
was replaced, perform another scan.
SUPFnc (hexadecimal number)
Value for the version of the storage system support function used
in the copy group (minimum)
# The CAJ ATTIME Suspend Function can be used in a storage system
where the version of the storage system support function are X'14' or
higher.
This device SUPFnc does not support
CAJ ATTIME.
YKZ412E MSG
SC=36 RC=48
Messages 209