HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)

Explanation and recommended actionsMessage textMessage ID
The user SVC is not registered, or the &YKSVCNO system symbol of the
IEASYMxx parmlib member is specified incorrectly.
When the user SVC is defined in SVCPARM:
Make sure that the &YKSVCNO system symbol of the IEASYMxx
parmlib member is specified correctly.
When the user SVC is not defined in SVCPARM:
Register the user SVC by YKALCSVC command.
For details about registering a user SVC, see the HP XP7 for Business
Continuity Manager Software Installation Guide.
SVC # is null or invalid.
YKZ300E MSG TSO
SC=44 RC=44
The task is not authorized to execute a CLI command. The program
will terminate.
For details about how to set CLI command execution permissions, see
the HP XP7 Smart Manager for Mainframe User Guide.
XXYYZZZZ
Reason code
If the reason code is 00000010, 00000040, or 000000C0:
The user might not have been given the permissions to view the
STGADMIN.YKA.DKT.COMMANDS profile or the STGAD-
MIN.YKA.DKT.KTQUERY profile. Check and, if necessary, revise
the profile setting.
If the reason code is 00000050 or 000000D0:
The user might not have been given the permissions to view the
STGADMIN.YKA.DKT.COMMANDS profile. Check and, if necessary,
revise the profile setting.
If the reason code is other than the above:
The information returned from the RACROUTE REQUEST=AUTH
macro is displayed in the following format. For details, see the
Security Server RACROUTE Macro Reference.
- XX: Lower 1 byte of SAF RC of the RACROUTE macro
- YY: Lower 1 byte of RACF RC of the RACROUTE macro
- ZZZZ: Lower 2 bytes of RACF Reason Code of the RACROUTE
macro
The task is not authorized to execute
the request. (reason
code=XXYYZZZZ)
YKZ301E CON
The task is not authorized to execute a CLI command. The program
will terminate abnormally with user completion code 128 or will return
an error.
reason
Reason code
For details, see the description for that user completion code.
For details about how to set CLI command execution permissions, see
the HP XP7 for Business Continuity Manager Software Installation Guide.
The task is not authorized to execute
the request. (reason code=reason)
YKZ301E CON
RC=128
Messages198