HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)
Table Of Contents

Explanation and recommended actionsMessage textMessage ID
subCTGroupID in the copy group structure is either NULL or invalid.
Correct the configuration file, and then execute the YKLOAD command.
value
REXX variable value
# If this message is output while the YKLOAD command is being
executed, the RC is 44.
subCTGroupID value null or invalid.
YKZ283T MSG
SC=36 RC=36
#
UR_MirrorID in the copy group structure is either NULL or invalid.
Correct the configuration file, and then execute the YKLOAD command.
value
REXX variable value
# If this message is output while the YKLOAD command is being
executed, the RC is 44.
UR_MirrorID value null or invalid.
YKZ284T MSG
SC=36 RC=36
#
The YKBLDPTH, YKDELPTH, and YKQRYPTH commands cannot be
executed for a logical path without a port element both on primary
and secondary direction. Only the YKQRYPTH command with a
RESTRUCT parameter can be executed on a logical path without a
port element.
To execute one of these commands against a logical path, correct the
configuration file and then execute the YKLOAD command.
index
Index number of the logical path without a port element
This command cannot be executed
without a port.
YKZ285I MSG SC=0
RC=0 (index)
When the YKQRYPTH command is executed on a storage system that
has not been directly connected to the host for the path set of an
inter-control unit logical path, the volume belonging to the originally
established inter- control unit of the inter-control unit logical path must
have been scanned at least once.
Make sure that the volume belonging to the targeted control unit has
been scanned at least once, and the control unit and command control
address defined for the path set are correct. If the command control
address is not defined for the path set, from the Edit Logical Path
Definition panel, specify the command control address of the volume
scanned in the target control unit for path control.
index
Index number of the logical path that cannot be executed
YKQRYPTH command cannot be ex-
ecuted if the volume on the CU type
path has not been scanned.
YKZ286E MSG
SC=36 RC=36 (in-
dex)
UR_PathID in the copy group structure is either NULL or invalid.
Correct the configuration file, and then execute the YKLOAD command.
value
REXX variable value
#
If this message is output while the YKLOAD command is being ex-
ecuted, the RC is 44.
UR_PathID value null or invalid.
YKZ287T MSG
SC=36 RC=36
#
Messages192