HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)
Table Of Contents

Explanation and recommended actionsMessage textMessage ID
The IFType of a storage system using the Remote DKC Control Function
is smaller than the IFType of the S-VOL defined in the copy group.
As such, the smaller of the two will be used when each command is
executed. Note that on some machine types, some functionality might
be lost. Also, if a scan was not performed after the storage system
microcode was replaced, perform another scan.
value
IFType value of the remote storage system
Secondary volume's IFType is larger
than Remote control's IFType value.
YKZ280W MSG
SC=0 RC=0
The device specified during command device usage does not support
the Remote DKC Control Function.
Check whether the device can use the Remote DKC Control Function
#2
, and then revise the Remote DKC Control Function definitions.
Storage System's-IFType
IFType value of the storage system
#1
If this message is output while the YKLOAD command is being ex-
ecuted, the RC is 44.
#2
The Remote DKC Control Function can be used in a storage system
on the XP1024/XP128 models (or later) where the first two digits
of the IFType are X'04' or higher.
Some of the storage systems do not
support Remote Control.
YKZ281E MSG
SC=36 RC=36
#1
(Storage Sys-
tem's-IFType)
Continuous Access Journal cannot be used on a storage system that
has a P-VOL or uses the Remote DKC Control Function.
Use a device
#2
that supports Continuous Access Journal. Also, if a scan
was not performed after the storage system microcode was replaced,
perform another scan.
IFType
IFType value
#1
If this message is output while the YKLOAD command is being ex-
ecuted, the RC is 44.
#2
The Continuous Access Journal is used in a storage system where
the first two digits of the IFType are X'11' or higher.
Primary device IFType does not
support CAJ.
YKZ282E MSG
SC=36 RC=36
#1
Continuous Access Journal cannot be used on a storage system that
has an S-VOL or uses the Remote DKC Control Function.
Use a device
#2
that supports Continuous Access Journal. Also, if a scan
was not performed after the storage system microcode was replaced,
perform another scan.
IFType
IFType value
#1
If this message is output while the YKLOAD command is being ex-
ecuted, the RC is 44.
#2
The Continuous Access Journal is used in a storage system where
the first two digits of the IFType are X'11' or higher.
Secondary device IFType does not
support CAJ.
YKZ282E MSG
SC=36 RC=36
#1
Messages 191