HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)
Table Of Contents

Explanation and recommended actionsMessage textMessage ID
An I/O error occurred. Processing will continue with this device
skipped.
If a sense byte is set, the sense byte is indicated in the YKZ255E
message.
When CC=3:
The corresponding device might not be configured or connected.
When CC=0 and CSW=xxxxxx0000xxxx (DSB=00, CSB=00) where
x indicates a value:
The corresponding device might not be configured or connected.
When CC=0 and CSW=0000000006xxxx where x indicates a value:
MIH might have occurred or a logical path might not be connected.
device-number-1 (string)
The device that issued I/O
device-number-2 (string)
The device to be manipulated
If the device number of the device to be operated is not found,
**** is displayed.
code1 (decimal number)
CC information
code2 (Hexadecimal number)
CSW information
code3 (Hexadecimal number)
Subcommand code
code4 (Hexadecimal number)
Completion code
code5 (Hexadecimal number)
Detailed code
xxx (decimal number)
Command code of the command that was executing when the
error occurred
See the command code description in the explanation of the
YKZ201E message.
yyy (string)
Maintenance information
pair-index
See the pair index description in the explanation of the YKE003E
message.
DASD device device-number-
1(device-number-2) I/O error.
(CC=code1
CSW=code2code3code4code5,
cmd=xxx, pos=yyy).
YKZ253E MSG
SC=32 RC=32
(pair-index)
Messages 181