HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)

Explanation and recommended actionsMessage textMessage ID
For the specified model, TRK cannot be specified for TCA_MAP in the
Continuous Access Asynchronous options.
Correct the contents of the configuration file.
stem
Stem name
# If this message is output while the YKLOAD command is being
executed, the RC is 44.
stemTCA_MAP=TRK not supported
by some group pairs
YKZ226E MSG
SC=36 RC=48
#
Some copy pairs in this group do not support TCA_FLOWCONTROL=N.
Correct the configuration file, and then re-execute the YKLOAD
command.
stem
Stem name
# If this message is output while the YKLOAD command is being
executed, the RC is 44.
stemTCA_FLOWCONTROL=N not
supported by some group pairs.
YKZ227E MSG
SC=36 RC=36
#
The value of the REXX variable is invalid.
Check that the value is specified according to the following rules:
The command control address must consist of 2 digits.
The control unit number must consist of 2 digits.
The storage subsystem ID (SSID) must consist of 4 digits.
The storage system serial number must consist of 5 digits.
The device number must consist of up to 4 digits.
name
REXX variable name
value
Value
pair-index
See the pair index description in the explanation of the YKE003E
message.
# If this message is output while the YKLOAD command is being
executed, the RC is 44.
Invalid pair attribute name = value
YKZ228E MSG
SC=36 RC=36
#
(pair-index)
The time assigned to the ATTIME parameter has elapsed. Processing
will continue, ignoring the specification of the ATTIME parameter.
The time specified with ATTIME has
past. The specification of ATTIME is
ignored.
YKZ229I MSG SC=0
RC=0
Messages174