HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)

Explanation and recommended actionsMessage textMessage ID
The information in the configuration file has been updated since it was
last obtained.
Refresh the configuration file from Replication Manager, and then retry
the operation.
The information in configuration file
was updated after you obtained it.
YKY728E XML
The contents of the configuration file are invalid.
See the other error message that was output with this message, and
then use Replication Manager to correct the error. After that, update
the configuration file again.
file
Name of the configuration file in which an error was detected
Configuration file is invalid. file
YKY729E XML
The specified consistency group is invalid.
Make sure that the specified C/T group exists in the copy group
definition file.
INVALID CT Group is specified.YKY730E XML
A REXX script that cannot be used by XP7 mainframe agent was
executed.
Check the REXX Exec library connected to SYSEXEC dd name.
MFAgent cannot use this REXX exec
library.
YKY999E TSO CON
Table 36 List of messages (message ID YKZ0x)
Explanation and recommended actionsMessage textMessage ID
Invalid parameters were specified.
For details, see the reason code in the YKZ099I message displayed
after this message. For more information about reason codes, see
IKJPARS in the TSO/E Programming Services.
Supplied parameters invalidYKZ000T TSO SC=48
Nothing is assigned to the parameter identified by parameter-name.No parameter-name() supplied
YKZ001E TSO MSG
SC=48
The last character of the string assigned to the parameter identified by
parameter-name is not a period.
parameter-name() does not in-
clude trailing "."
YKZ002E MSG
SC=48
The value assigned to the parameter identified by parameter-name
is invalid.
parameter-name() value invalid
YKZ003E MSG
SC=48
The device specified in the DEVN parameter does not exist, or a device
other than DASD or a PAV ALIAS volume has been specified.
Device# DEVN() is not found.
YKZ004E MSG
SC=48
The value specified in the parameter identified by parameter-name
is not in hexadecimal format.
parameter-name() not valid hex
YKZ008E MSG
SC=48
An attempt to access the REXX variable identified by name has failed.
For details about the return code, see IKJCT441 in the TSO/E
Programming Services.
nnnn
Error code returned upon REXX access
REXX failure return code=nnnn
starting with variable name
YKZ010E MSG
SC=48
Messages162