HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)

Explanation and recommended actionsMessage textMessage ID
The route label must be a combination of one or more qualifiers. Each
qualifier must be from 1 to 8 alphanumeric characters (0-9, A-Z, a-z),
and must start with an alphabetic character (A-Z, a-z). The length of
the route label must be from 1 to 8 characters.
Route Label must be a combination
of one or more qualifiers. Each
qualifier must be 1-8 alphanumeric
characters (0-9, A-Z, a-z) with the
first character being an alphabetic
character (A-Z, a-z). The length of
Route Label must be 1-8.
YKM776E ISPF
Table 15 List of messages (message ID YKM90x)
Explanation and recommended actionsMessage textMessage ID
Start the YKSTART command.
Start YKSTART command.YKM900E ISPF
The ISPF service is not available.
Execute the YKSTART command in an ISPF environment.
After that, you can execute whichever Business Continuity Manager
commands you need to.
ISPF service is not available.YKM901E TSO
The Business Continuity Manager load module was not found. The
Business Continuity Manager dataset might not be concatenated to the
LNKLST.
Revise the settings for the LNKLST, and then execute the YKSTART
command.
After that, you can execute whichever Business Continuity Manager
commands you need to.
Load module is not found.YKM902E TSO
The SELECT service terminated abnormally with the return code nn.
If this message is displayed immediately after executing the YKSTART
command, the Business Continuity Manager dataset might not be
concatenated to the panel library (dd name: ISPPLIB), the table library
(dd name: ISPTLIB), or the REXX exec library (dd name: SYSEXEC).
If DBCS (Double-Byte Character Set) is enabled for the environment,
concatenate the Business Continuity Manager dataset to the alternate
panel library (dd name: ISPPALT). For details, see the HP XP7 for
Business Continuity Manager Software Installation Guide.
nn
Return code of the service
SELECT service terminated abnor-
mally. RC=nn
YKM903E TSO
The message library was not found.
The Business Continuity Manager dataset might not be concatenated
to the message library (dd name: ISPMLIB).
If DBCS (Double-Byte Character Set) is enabled for the environment,
concatenate the Business Continuity Manager dataset to the alternate
message library (dd name: ISPMALT). For details, see the HP XP7 for
Business Continuity Manager Software Installation Guide.
Message library was not found.YKM904E TSO
A GETMAIN error occurred. The program will stop running.
Contact Technical Support for assistance.
A GETMAIN error occurred.YKM905E TSO
Messages124