HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)
Table Of Contents

Explanation and recommended actionsMessage textMessage ID
No command device was found that is defined in the route for remote
command issuance or with the specified route label.
Correct the route definition in the route list definition file identified by
file.
file
Name of the configuration file where the error was detected
rec#
Number of the line in the file identified by file where the error
was detected
No command devices are defined
for routes that issue remote com-
mands or for route labels.
YKL281E MSG
SC=36 RC=36
(file:rec#)
The route label specified for the ROUTE parameter is not defined.
Correct the route definition in the route list definition file identified by
file.
file
Name of the configuration file where the error was detected
The route label specified for the
ROUTE parameter has not been
defined.
YKL282E MSG
SC=36 RC=36 (file)
An attempt was made to load command device lines for which no route
label is specified because no route label is specified for the ROUTE
parameter. However, route labels are defined for all the command
devices in the route list definition file shown in file.
Set an appropriate route label for the ROUTE parameter of the YKLOAD
command, or use the Edit Attribute panel to delete the route labels of
command devices in the route list definition file shown in file.
file
Name of the configuration file where the error was detected
A route label is not specified for the
ROUTE parameter, even though a
route label is defined for all the
command devices.
YKL283E MSG
SC=36 RC=36 (file)
In a file for a copy group of the Business Copy copy type, a copy pair
has been discovered for which the storage system serial numbers of
the P-VOL and S-VOL do not match.
Correct the line with the line number identified by rec# in the file
identified by file.
file
Name of the configuration file where the error was detected
rec#
Number of the line in the file identified by file where the error
was detected
PVOL & SVOL of BC pair is in the
different storage system.
YKL284E MSG
SC=36 RC=36
(file:rec#)
An attempt to acquire the variable vn failed with the result value
identified by result. This error can be caused by an invalid value
being specified for the STEM parameter.
YKVGET program failure for: vn
YKL290E MSG
SC=44 RC=44 (res-
ult)
The license key for the function identified by function-name has not
been installed, has expired, or is not correctly recognized.
Check whether the license key is available for this version.
If function-name is This product:
Business Continuity Manager commands cannot be used because
the Business Continuity Manager license key has not been installed.
If function-name is CAJ 4x4 Extended CTG:
The function for preserving consistency on an EXCTG basis cannot
be used because the license key required for a 4x4 configuration
has not been installed.
function-name is not licensed for
use on this system.
YKL291E MSG
SC=36 RC=36
Messages112