HP XP7 Command View Advanced Edition Release Notes (TK981-96008, May 2014)
Virtualizing storage devices
If you perform a volume virtualization task created under all of the following conditions in the Virtualize
Volumes dialog box, the task generates a KAIC15001-E error:
• The external paths are set to the volumes that are selected when you launch the Virtualize Volumes
dialog box.
• Both of the ports on the internal storage side and external storage side in the external paths
described in the first condition are selected.
Virtualize a storage device by either of the following methods:
Using the GUI: Perform either of the following operations, and then retry the volume virtualization task.
• Cancel the external path assigned to the external volumes.
• Create a new path by selecting a port other than the ports of the internal storage system, or by
selecting a port other than the ports of the external storage system.
Not using the GUI:
• CLI AddExternalArrayGroup command.
• Element Manager, Remote Web Console, or XP Remote Web Console.
Storage device virtualization tasks
If a storage device virtualization task failed by interception, the volume of an external storage system
may remain being allocated to an internal storage system.
If this occurs, virtualize a storage device with either of the following methods:
Using the GUI:
Perform either of the following operations, and then retry the volume virtualization task.
• Cancel the external path assigned to the external volumes.
• Create a new path by selecting a port other than the ports of the internal storage system, or by
selecting a port other than the ports of the external storage system.
Not using for GUI:
• CLI AddExternalArrayGroup command.
• Element Manager, XP P9000 Remote Web Console, or XP Remote Web Console.
NOTE: If the solution is not performed and a storage device virtualization task specifying the remaining
volumes is executed, the task generates the KAIC15001-E error. If this occurs, perform the solution
above.
Changing the access port number of the HBase Storage Mgmt Web Service
To change the access port number of the HBase Storage Mgmt Web Service, do not specify the
following ports:
• 1(tcpmux)
• 7(echo)
• 9(discard)
• 11(systat)
• 13(daytime)
• 15(netstat)
• 17(qotd)
• 19(chargen)
Important considerations 45