HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)

Command execution example
hdvmcli AddArrayReservation -o "D:\logs\AddArrayReservation.log"
"model=XP12000" "serialnum=14009"
Command execution result
An instance of ArrayReservation
objectID=*****
target=*****
serialNumber=14009
arrayType=XP12000
loginID=dmuser
beginTime=1,039,003,476
*****: The values are encoded by the CLI.
AddExternalArrayGroup
AddExternalArrayGroup performs one-to-one mapping of external volumes (volumes in an externally
connected storage system) to internal volumes, and then creates a parity group.
AddExternalArrayGroup also creates an LU in the created external parity group. When you
perform mapping, you can specify multiple paths (alternate paths).
NOTE:
This command can be used only with HP XP7, P9500, and XP24000/XP20000. The microcode
version required for XP24000/XP20000 is 60-02-40-XX/XX or later.
Before you can execute this command, both the storage system in which to create an external
parity group and the externally connected storage system must be registered as management
targets of Device Manager.
Parameters
Table 23 AddExternalArrayGroup command parameters
DescriptionStatusParameter name
Serial number of the storage system where you want to create
the external parity group
Required
serialnum
Model of the storage system where you want to create the external
parity group
Required
model
Number of the external parity group
Specify the number of the external parity group to be created.
You can specify an integer from 1 to 16384.
If this parameter is omitted, a value is automatically set by Device
Manager.
Optional
externalgrpnum
CLI Reference Guide 63