HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)
DescriptionAttribute
Time at which the alert occurred (example: 2008/04/06 20:13:56)
If type is Server, the time at which the Device Manager server obtained the
alert is output, and if type is Trap, the time at which the alert occurred on the
storage system is output.
timeOfAlert
ArrayGroup instance
Commands for which an ArrayGroup instance is output
• AddExternalArrayGroup, page 63
• AddPool, page 99
• AddVirtualVolume, page 121
• GetStorageArray (subtarget=ArrayGroup) , page 178
• GetStorageArray (subtarget=FreeSpace) , page 190
• GetStorageArray (subtarget=PDEV) , page 216
• GetStorageArray (subtarget=Pool) , page 218
• ModifyPool, page 261
Table 137 ArrayGroup instance attributes
DescriptionAttribute
Object ID of the parity group
objectID
Parity group name
This item is output if it has been registered.
name
Number of the chassis containing the parity group
chassis
Parity group number
number
Display name of the parity group (example: 1, 1-1, 2-1-1, S3-1)
S in the above format indicates the type of the parity group.
• E: Parity group of an External volume
• V: Parity group of V-VOL
• X: Parity group of a THP volume
displayName
RAID type of the parity group
The RAID type is output in the format RAIDx(yD[+zP]) or RAIDx(yD[+yD]).
• RAIDx: RAID level
• yD: Number of data drives
• zP: Number of parity drives
For example, RAID5(3D+1P) indicates a RAID5 configuration consisting of three
data drives and one parity drive.
raidType
Emulation mode
This item is output for the XP24000/XP20000, XP12000/XP10000/SVS200, or
XP1024/XP128 (example: OPEN-8).
emulation
Output items428