HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)
Command execution result 1
RESPONSE:
An instance of ReplicationGroup
objectID=*****
replicationGroupID=0
groupName=HCMD_CG0003
pvolHostID=1
pvolInstanceNumber=11
pvolPortNumber=50,001
pvolHORCMMONHostName=192.168.32.63
pvolHORCMINSTHostName=192.168.32.63
svolHostID=1
svolInstanceNumber=12
svolPortNumber=50,002
svolHORCMMONHostName=192.168.32.64
svolHORCMMONHostName=192.168.32.64
replicationFunction=ContinuousAccessSync
fenceLevel=Data
copyTrackSize=15
List of 1 ReplicationInfo elements:
An instance of ReplicationInfo
objectID=*****
pairName=HCMD_CP0004
pvolSerialNumber=65010001
pvolArrayType=XP1024
pvolDevNum=5
displayPvolDevNum=00:05
pvolObjectID=*****
pvolPoolID=-1
svolSerialNumber=65010012
svolArrayType=XP1024
svolDevNum=10
displaySvolDevNum=00:0A
svolObjectID=*****
svolPoolID=-1
fenceLevel=Data
replicationFunction=ContinuousAccessSync
status=1
muNumber=-1
copyTrackSize=15
splitTime=-1
remotePathGroupID=-1
pvolMngAreaPoolID=-1
svolMngAreaPoolID=-1
snapshotGroupID=-1
confPvolSerialNumber=65010001
confPvolDevNum=5
confSvolSerialNumber=65010012
confSvolDevNum=10
*****: The values are encoded by the CLI.
Command execution example 2
This example creates a copy group in the existing RAID Manager configuration definition file and
creates a copy pair for Business Copy. As the primary volume (P-VOL), specify the logical device with
LDEV number 11 in the storage system with model number XP1024 and serial number 15001. The
CLI Reference Guide 403