HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)
DescriptionStatusParameter name
Starting sequence number of host storage domains that belong
to a physical resource group and from which you want to obtain
information
Specify this parameter when you want to obtain information for
a part of host storage domains for a specific storage system.
When host storage domain information is ordered as shown
below and numbered from 0 upward, specify the first number in
the sequence of host storage domains that you want to obtain.
Order of host storage domains:
1. Port IDs in ascending order
2. Domain IDs in ascending order
If you specify this parameter, you must also specify the
serialnum, model, rpuid, and numOfPagElementsFilter
parameters.
Optional
startPhsdEle-
mentNumFilter
Number of the first host storage domain that belongs to a physical
resource group and for which information is obtained
Specify this parameter when you want to obtain information for
a part of host storage domains for a specific storage system.
Specify the number of host storage domains for which information
is to be obtained. This parameter must be specified together with
the model, serialnum, rpuid, and
startPhsdElementNumFilter parameters. Specify
PHostStorageDomain for the prpusubinfo parameter.
The maximum recommended value is 4096. Make sure that the
sum of the values you specify for the
startPhsdElementNumFilter and
numOfPhsdElementsFilter parameters is in the range from
1 to 2,147,483,647.
Optional
numOfPhsdEle-
mentsFilter
Starting sequence number of LDEVs that belong to a physical
resource group and for which you want to obtain information
Specify this parameter when you want to obtain virtual information
about only some of the LDEVs in a specific storage system.
When LDEV information is in ascending order and starts from 0,
specify the first number in the sequence of LDEV information to
be obtained.
If you specify this parameter, you must also specify the
model,serialnum , rpuid, and
numOfPldevElementsFilter parameters.
Optional
startPldevEle-
mentNumFilter
Number of the first LDEV that belongs to a physical resource group
and for which information is obtained
Specify this parameter when you want to obtain virtual information
about only some of the LDEVs in a specific storage system. If you
specify this parameter, you must also specify the model,
serialnum, rpuid, and startPldevElementNumFilter
parameters. Specify PLDEV for the prpusubinfo parameter.
The maximum recommended value is 4096. Make sure that the
sum of the values you specify for the
startPldevElementNumFilter and
numOfPldevElementsFilter parameters is in the range from
1 to 2,147,483,647.
Optional
numOfPldevEle-
mentsFilter
Command reference232