HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)

. (repeated for other Pool instances)
.
*****: The values are encoded by the CLI.
GetStorageArray (subtarget=Port)
GetStorageArray (subtarget=Port) obtains the information about ports.
Parameters
Table 75 GetStorageArray (subtarget=Port) command parameters
DescriptionStatusParameter name
Specify Port.
Required
subtarget
Serial number of the storage system
If you omit this parameter, all the storage systems become the
target.
Optional
serialnum
Model of the storage system
If you omit this parameter, all the storage systems become the
target.
Optional
model
Number of the port of the storage system
Specify this parameter when you want to obtain information about
a specific port. If port and portname are omitted, information
about all ports is displayed. If you specify this parameter, you
must also specify the model and serialnum parameters.
Do not specify port and portname at the same time. If they are
specified at the same time, an error occurs.
Optional
port
Port name for the storage system
Specify this parameter when you want to obtain information about
a specific port. If port and portname are omitted, information
about all ports is displayed. If you specify this parameter, you
must also specify the model and serialnum parameters.
Do not specify port and portname at the same time. If they are
specified at the same time, an error occurs.
Optional
portname
Specific information about the ports
The values you can specify are HostStorageDomain, WWN,
and VPort. If you specify multiple values at the same time,
separate the values by commas.
You can specify VPort only for HP XP7 or P9500 (with a
microcode version of 70-03-30-XX/XX or later).
Optional
portsubinfo
Type of port about which you want to obtain information
The values you can specify are LCP, Fibre, SCSI, FICON, NAS,
ISCSI, and FCoE.
If you specify multiple values at the same time, separate the values
by semicolons (;).
Optional
portfilter
CLI Reference Guide 225