HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)

DescriptionStatusParameter name
Information about a logical unit
The values you can specify are Path and LDEV. If you specify
multiple values at the same time, separate the values by commas.
If you specify this parameter, you must also specify
arraygroupsubinfo=LogicalUnit.
Optional
lusubinfo
Starting sequence number of parity groups for which information
is to be obtained
Specify this parameter when you want to obtain information for
a part of parity groups in a specific storage system.
When parity group information is ordered as shown below and
numbered from 0 upward, specify the first number in the sequence
of parity groups that you want to obtain.
Order of parity groups:
1. Chassis numbers in ascending order
2. Parity group numbers in ascending order
This parameter must be specified together with the
numOfElementsFilter, model, and serialnum parameters.
Optional
startElement-
NumFilter
Number of parity groups for which information is to be obtained
Specify this parameter when you want to obtain information for
a part of parity groups in a specific storage system. Specify the
number of parity groups for which information is to be obtained.
This parameter must be specified together with the
startElementNumFilter, model, and serialnum
parameters.
The maximum recommended value is 16384.
Optional
numOfElements-
Filter
Parity group name
The following value specification formats can be used:
n
n - n
n - n - n
E n - n
V n -1
X n -1
Here, n is an integer of 1 or greater, while E, V, and X are fixed.
If this parameter is specified, the model parameter must also be
specified.
Optional
arraygroupname
Filter used to select parity groups that belong to a specific physical
resource group
Specify the ID of the physical resource group that contains the
parity groups.
Optional
rpuidfilter
Parameter values to obtain in advance
serialnum and model
CLI Reference Guide 179