HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)
• If both internal and external volumes are used for a THP/Smart pool, the cache mode for the ex-
ternal volumes must be ON.
However, if a THP/Smart pool was created when the microcode version was earlier than 70-02-
00-XX/XX, the THP/Smart pool cannot contain both internal and external volumes, even if the
microprogram is upgraded to 70-02-00-XX/XX or later.
The following conditions apply only to P9500 with a microcode version of 70-02-00-XX/XX or later,
or earlier than 70-04-00-XX/XX:
• If more than one logical unit is specified for a THP/Smart pool, up to three types of logical units
with different drive types or rotational speeds can be used.
#
However, logical units with the same drive type and rotational speed must also have the same
RAID level.
• If the microcode version is earlier than 70-03-30-XX/XX and more than one logical unit is specified
for a THP/Smart pool, RAID 1 must not be mixed together with other RAID levels.
#
The specifiable drive types are SSD, SAS, and SATA. Only SAS drives are distinguished by the
rotational speed.
Only one type of external volume is allowed, regardless of the drive type and rotational speed
of the actual volumes.
The following conditions apply only to XP24000/XP20000:
• If more than one logical unit is specified, internal volumes and external volumes cannot be mixed
together.
• If more than one internal volume is specified, all of them must have the same drive type.
For external volumes, HP does not recommend that you use logical units with different drive types
for a THP pool.
• If more than one logical unit is specified, all of their drives must have the same rotational speed.
• If more than one logical unit is specified, all of them must have the same CLPR number.
NOTE:
The following conditions depend on the specifications of the Thin Provisioning functionality of the
storage system:
• The number of pool volumes that can be specified in a THP/Smart pool
• The total maximum number of THP/Smart pools, Snapshot pools, and Fast Snap pools
Format for HP XP7 and P9500
hdvmcli [URL] AddPool [options]
model=model serialnum=serial-number [poolid=pool-ID]
[threshold=THP/Smart-pool-threshold-1]
[threshold2=THP/Smart-pool-threshold-2] [threshold2mode={0|1}]
[overprovisioningwarning=over-provisioning-warning-threshold]
[overprovisioninglimit=over-provisioning-limit-threshold]
devnums=device-number-of-logical-unit
[tiercontrol={enable|disable}]
[automigration={enable|disable}] [migrationinterval={0|1|2|4|8|24}]
[monitorstarttime=start-time-of-performance-monitoring]
[monitorendtime=end-time-of-performance-monitoring]
Command reference100