HP XP7 Command View Advanced Edition Administrator Guide (Web Version) (TK981-96004, May 2014)
CAUTION:
• If the GUI displays a warning message, manually refresh the corresponding storage system inform-
ation.
You can also specify the settings so that information in the database is automatically updated in
case a user forgets to perform a manual refresh after changing the storage system configuration.
To do so, set up the following properties:
server.dispatcher.daemon.autoSynchro.doRefresh property
server.dispatcher.daemon.autoSynchro.type property
• The Device Manager server cannot detect the following configuration changes:
- Changes in the LDEV status (such as normal, blocked, or being copied).
- Creating, changing, or deleting copy pairs
In addition, the Device Manager server cannot detect changes to the access attribute of LDEVs
(such as Read/Write, Read Only, or Protect) that are performed on XP24000/XP20000.
• In the Device Manager server the configurations of storage system are treated as changed for the
following triggers:
- Restarting SVP
- Refreshing the configuration information of storage system displayed in Remote Web Console.
- Switching the SVP in a cluster configuration from the executing node to the standby node, or
vice versa.
- Turning on the DKC
- The configuration of a THP/Smart pool is changed
#
The configuration of the Snapshot data pool or the Fast Snap data pool is changed
#
#:
For HP XP7 or P9500, if you specify false for the server.dispatcher.daemon.configUp-
date.detection.variable.enabled property, you can prevent a warning message from
being displayed in the Device Manager GUI when the pool configuration is changed.
Related topics
• server.dispatcher.daemon.autoSynchro.doRefresh, page 331
• server.dispatcher.daemon.autoSynchro.type, page 332
• server.dispatcher.daemon.configUpdate.detection.variable.enabled, page 333
server.dispatcher.daemon.autoSynchro.doRefresh
Specify whether to automatically refresh the storage system information in the database if the Device
Manager server detects that the configuration of an HP XP7, P9500 or XP24000/XP20000 storage
system has changed.
If true is specified for this property and a user does not perform a manual refresh after the Device
Manager server detects a change, the information of HP XP7, P9500 or XP24000/XP20000 in the
database is automatically refreshed at the interval specified in the
server.dispatcher.daemon.autoSynchro.type property. If false is specified, the database
is not automatically refreshed.
Default: true
Administrator Guide (Web Version) 331