HP XP7 Command View Advanced Edition 8.0.0-01 Release Notes
◦ Volume capacity of external storage system specified for the externallun parameter is
greater than 4,294,967,296 KB (4.0 TB).
◦ The capacity parameter is omitted or is specified for a volume capacity that is greater than
4,294,967,296 KB (4.0 TB).
If this occurs, virtualize a volume using Element Manager.
Creating a Smart pool in XP P9500
In the Create Pool dialog box, if operations for creating a Smart pool meet all of the following conditions,
creating the Smart pool may generate the KAIC07861-E error indicating that the cycle time is invalid:
• An XP P9500 whose microcode version is earlier than 70-02-00-00/00 is selected in the Storage
System box.
• Smart is selected as pool type.
• Auto is selected as tier management of Smart Options.
If this occurs, select 24 hours in the Cycle time box, then select the Show Plan button.
Values displayed in Removable column of pool volume list
If Yes appears in the Removable column of the pool volume list, removing pool volume in shrink pool
process may not succeed under any of the following conditions.
• The pool usage rate has exceeded the Depletion Threshold, or the pool status is blocked.
• The pool volume status is blocked.
• If the pool volume is removed, the pool usage rate exceeds Depletion Threshold, or the pool
subscription rate exceeds Subscription Limit.
Using the CIM/WBEM service discovery function in a server machine with multiple IP
addresses
When a server machine with Device Manager installed has multiple IP addresses, choose an IP address
that connects the CIM client to the server, and then add that IP address in the following property file:
Property name: com.wbemsolutions.jserver.bindto
Properties file name: jserver.properties
Properties file location:
• In Windows:installation-folder-for-the-Device-Manager-server\Server\config
• In Linux:installation-directory-for-the-Device-Manager-server/Server/config
Important considerations 27